[. . . ] Within the market of premium audio it is vital to offer exceptional performance and value for money. Products must be made to the highest of standards, be reliable and attractive. A manufacturer must offer exceptional service, dealer training, support and undertake the very best in promotion design and literature. If all these elements are in place customers should experience excellence at every stage. [. . . ] Areas where `tube' amplifiers are present should not exceed 25 °C. If you are positioning the Titan in the close proximity of such a device please be aware of this factor. NO ! If you have to locate the unit on the floor we strongly recommend you do not place the unit near heat sources, such as radiators or air ducts. Good air circulation is essential to prevent heat build up within the chassis. Do not place the Titan on a soft surface, for example a rug or carpet, which could block the ventilation intakes on the bottom half of the chassis. Should either of these events happen immediately switch off the unit at the wall socket, wait for at least one minute, unplug all other cables and return it to your authorised IsoTek dealer for a full service. November 2004 C. Installation Placement Ideally the unit should be placed upon its own dedicated shelf of an audio grade equipment rack. Titan may also be placed next to the power amplifier it supplies however if you have to locate the unit on the floor or in any other location other than an equimpment rack please refer to the safety section of this manual. Once the Titan is positioned connect the unit to a mains wall socket by the cable supplied. Firstly connect the blue Neutrik end of the power cord into the blue socket on the bottom left had side of Titan's back panel. Ensure that the silver release catch on the blue Neutrik plug is slightly to the left of 12 o'clock, push in and rotate clock wise until the plug clicks into place. Now plug the standard UK three pin, European Schuko or American three pin into the wall socket. Switch on the wall socket if it has a switch, and then turn on the Titan via the central on/off switch at the rear. Although every Titan is rigorously factory tested prior to dispatch, one thing we cannot test for is that your home earth/ground connection (yellow and green in European regulations) is functioning correctly. This is very important for the Titan's operation so the following test needs to be carried out. The supplied `Network Test Plug' will check the safety of your earthing within your home. Take the Network Test Plug and insert it into either output 1 or output 2 of Titan (UK) or into the Grey Multi-Link output (Europe). On plugging this into the unit Titan should immediatly `trip' and turn itself off. If you are in the UK and this fails to happen contact your local electrician as it is more than likely that the earth in your home has become disconected. If you live in Europe, before calling your electrician check the live/neutral polarity of the mains. Please do not confuse the test facility on the power on/off switch at the back of the Titan. This is mearly a test of the switch unit NOT the network. Rear elevation of the unit Conecting Titan to a power supply Pre network test Power on/off switch test facility November 2004 C. Installation Equipment coupling Under no circumstances can Titan be run without proper earth/ground protection. [. . . ] This allows for use on radial circuits not protected by RCDs, allowed under British regulations as a cooker circuit. Dimensions: Weight: 275mm x 182. 5mm x 275mm (WxHxD) 12. 75Kg MAINS POWER IN MULTI-LINK OUT DANGER HIGH VOLTAGE Total (Nominal 230V) Power: 3, 680W Total (Continuous*) Power: Total (Transient) Power: 4, 600W 23, 000W * Titan circuit The IsoTek® Titan is designed and handmade in England www. isoteksystems. com Risk of electric shock. The Titan can also be used with either the Titan Multi-Link or our dedicated front end Nova power conditioner. Full details can be found from your local authorised IsoTek dealer or on our web site www. isoteksystems. com IsoTek Titan IsoTek Cables March 2004 G. [. . . ]